4/2 and 4/3 directional shut-off valves, Types Z4WEH and Z4WH

Rexroth
  • Size 16
  • Component series 5X
  • Maximum operating pressure 315 bar
  • Maximum flow 300 l/min
Download Brochure

general

Size16
WeightValve with one solenoidkg14.1
Valve with two solenoidskg14.4
Valve witch hydraulic actuationkg13.3
Switching time adjustmentkg0.8
3-way pressure reducing valvekg0.4
Plate for version “T”kg0.5
Installation positionany
Ambient temperature ranges (NBR seals)°C-30 … +50
Ambient temperature ranges (FKM seals)°C-20 … +50

hydraulic

Size16
Maximum operating pressurePort PExternal pilot oil supplybar315
Internal pilot oil supply (without pressure reducing valve)bar250
Internal pilot oil supply (with pressure reducing valve)bar315
Anschluss Abar315
Port Bbar315
Port Xbar315
Port Ybar315
Port Tbar315
Maximum flowl/min300
Minimum pilot pressurebar12
Maximum pilot pressurebar250
Pilot volume for switching processcm³4.9
Hydraulic fluid 1)see table
Hydraulic fluid temperature range (NBR seals)°C-30 … +80
Hydraulic fluid temperature range (FKM seals)°C-20 … +80
Viscosity rangemm²/s2.8 … 500
Maximum admissible degree of contamination of the hydraulic fluid 2)Class 20/18/15 according to ISO 4406 (c)
1)The ignition temperature of the process and operating medium used must be over the maximum solenoid surface temperature.
2)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
Hydraulic fluidClassificationSuitable sealing materialsStandards
Mineral oilHL, HLPNBR, FKMDIN 51524
Fast bio-degradable hydraulic fluidsVDMA 24568
Environmentally compatibleInsoluble in waterHETGNBR, FKM
HEESFKM
Soluble in waterHEPGNBR, FKM
Other hydraulic fluids on request

Notices!

Actuation of the manual override is only possible up to a tank pressure of approx. 50 bar. Avoid damage to the bore of the manual override! (Special tool for the operation, separate order, material no. R900024943). When the manual override is blocked, the actuation of the solenoid must be prevented!

The simultaneous actuation of the solenoids must be prevented!

Switching times (= Contacting at the pilot control valve until start of opening of the control edge in the main valve and change in the pressure value by 5 %)

Inductive position switch type QM: electrical connection

The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.

electrical

Connection voltage (DC voltage)V24
Voltage tolerance (connection voltage)+30 %/-15 %
Admissible residual ripple%≤ 10
Max. load capacitymA400
Switching outputs

PNP transistor outputs, load between switching outputs and GND
Pinout

1V24
2, 4Switching outputmA400
3Earthing (GND)V0