4WREQ

Rexroth
  • Size 6, 10
  • Component series 2X
  • Maximum operating pressure 315 bar
  • Maximum flow 180 l/min

general

Type4WREQ
Size610
Installation positionany, preferably horizontal
Ambient temperature range°C-20 … +50
Storage temperature range°C-20 … +80
Weightwithsandwich plate (3 sensors)kg3.68.5
without sandwich platekg2.46.5

hydraulic

Size610
Maximum operating pressurebar315
Maximum operating pressurePort P (sensor 100 bar)bar100
Port P (sensor 160 bar)bar160
Port P (sensor 250 bar)bar250
Port P (sensor 400 bar)bar315
Port T (sensor 100 bar)bar100
Port T (sensor 160 bar)bar160
Port T (sensor 250 bar)bar210
Port T (sensor 400 bar)bar210
Port A (sensor 100 bar)bar100
Port A (sensor 160 bar)bar160
Port A (sensor 250 bar)bar250
Port A (sensor 400 bar)bar315
Port B (sensor 100 bar)bar100
Port B (sensor 160 bar)bar160
Port B (sensor 250 bar)bar250
Port B (sensor 400 bar)bar315
Maximum flowl/min80180
Nominal flowl/min8
16
32
25
50
75
Hydraulic fluidsee table
Hydraulic fluid temperature range°C-20 … +70
preferably°C+40 … +50
Viscosity rangemm²/s20 … 380
preferablymm²/s30 … 46
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)Class 20/18/15 according to ISO 4406 (c)
Hysteresis%≤ 0.1
Range of inversion%≤ 0.05
Response sensitivity%≤ 0.05
Zero shift upon change ofHydraulic fluid temperature%/10 K< 0.15
Operating pressure%/100 bar< 0.1
1)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
Hydraulic fluidClassificationSuitable sealing materialsStandards
Mineral oils and related hydrocarbonsHL, HLPNBR / FKMDIN 51524
Flame-resistant   – containing waterHFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620)NBRISO 12922
Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.

Flame-resistant – containing water:
Maximum pressure differential per control edge 175 bar
Pressure pre-loading at the tank port > 20 % of the pressure differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP 50 % to 100 %

electrical

Size610
Voltage typeDirect voltage
Maximum current consumptionof the amplifierA2
of the amplifier (impulse current)A3
Maximum currentOutput stageA1.7
Signal partA0.3
Actuated time 1)%100
Maximum coil temperature 2)°C150
Protection class according to DIN EN 60529IP65 (If a suitable and a correctly mounted mating connector are used.)
Converter resolution (command/actual value signals)bits10
Power supplyV24
Supply voltage rangeV19,4 … 35
Earthing (GND)V0
Enable input range“A6”V9 … 35
“F6”V9 … 35
Command value inputUQ “A6”mA10
Command value input rangeUP “A6”mA0 … 10
IQ and IP “F6”mA4 … 20
Actual value outputUQ “A6”V± 10
Actual value output rangeUP “A6”mA0 … 10
IQ and IP “F6”mA4 … 10
Control voltageLevel as for pin 1
0 V reference potentialFor pins 3, 6, 8 and 11 (connected to pin 2 in valve)
Error output24 V (19.4 V to 35 V), 200 mA maximum load
1)Connect the valve to the supply voltage only when this is required for the functional sequence of the machine.
2)Due to the surface temperatures occurring at solenoid coils, the European standards ISO 13732-1 and ISO 4413 need to be adhered to.

Sensor technology

Overload protectionSensor 100 barbar200
Sensor 160 barbar320
Sensor 250 barbar500
Sensor 400 barbar800
Bursting pressureSensor 100 barbar400
Sensor 160 barbar640
Sensor 250 barbar1000
Sensor 400 barbar1600
Characteristic curve deviation%< 0.2
Hysteresis%< 0.1
Repetition accuracy%< 0.05
Long-term drift (1 year) under reference conditions%< 0.2