4WRKE

Rexroth
  • Size 10, 16, 25, 27, 32, 35
  • Component series 3X
  • Maximum operating pressure 350 bar
  • Maximum flow 3000 l/min

general

Type4WRKE
Size101625273235
Installation positionany, preferably horizontal
Ambient temperature range°C-20 … +50
Storage temperature range°C-20 … +80
Weightkg8.711.216.81731.534
Sine test according to DIN EN 60068-2-610 cycles, 10…2000.. 10 Hz with logarithmic frequency changing speed of 1 octave/min, 5 to 57 Hz, amplitude 1.5 mm (p-p), 57 to 2000 Hz, amplitude 10g, 3 axes
Noise test according to DIN EN 60068-2-6420…2000 Hz, amplitude 0.05g2/Hz (10gRMS) 3 axes, testing time 30 min per axis
Shock test according to DIN EN 60068-2-27Half-sine 15g / 11 ms, 3 times in positive and 3 times in negative direction per axis, 3 axes
Damp heat according to DIN EN 60068-2-30Variant 2: +25 °C … +55 °C, 90 % … 97 % relative humidity, 2 cycles á 24 hours

hydraulic

Size101625273235
Maximum operating pressurebar350
Maximum operating pressurePort Pbar315350210350
Anschluss Abar315350210350
Port Bbar315350210350
Operating pressure rangePilot control valve, pilot oil supplybar25 … 315
Maximum return flow pressurePort T, external pilot oil returnbar315250210250
Port T, internal pilot oil returnbar10
Port Ybar10
Maximum flowl/min170460870100016003000
Nominal flow 1)l/min25
50
100
125
150
200
220
220
350
500400
600
1000
Pilot flowinput signal 0 → 100%Port X and Yl/min4.18.511.713
Hydraulic fluid temperature range°C-20 … +80
preferably°C-40 … +50
Viscosity rangemm²/s20 … 380
preferablymm²/s30 … 45
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2)Pilot control valveClass 18/16/13 according to ISO 4406 (c)
Main valveClass 20/18/15 according to ISO 4406 (c)
Hysteresis%≤ 1
Response sensitivity%≤ 0.5
1)±10% with Δp = 10 bar, Δp = valve pressure differential
2)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

electrical

Size101625273235
Voltage typeDirect voltage
Type of signalanalog
Maximum current consumptionof the amplifierA1.5
of the amplifier (impulse current)A3
Protection class according to DIN EN 60529IP65 (If a suitable and a correctly mounted mating connector are used.)
Power supplyV24
Supply voltage rangeV18 … 35
Earthing (GND)V0
Command value input“A1”V10
Command value input range“F1”mA4 … 20
Actual value output“A1”V10
Actual value output range“F1”mA4 … 20
Hydraulic fluidClassificationSuitable sealing materialsStandards
Mineral oils and related hydrocarbonsHL, HLPNBR / FKMDIN 51524
Flame-resistant   – containing waterHFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620)NBRISO 12922
Phosphoric acid estersHFD-RFKM
Category: