Valve Hydraulic
Check valve, pilot operated Type Z2S
- Size 6
- Component series 6X
- Maximum operating pressure 315 bar
- Maximum flow 60 l/min
general
Size | 6 | ||
Weight | kg | 0.8 | |
Installation position | any | ||
Ambient temperature range | NBR seals | °C | -30 … +80 |
FKM seals | °C | -20 … +80 |
hydraulic
Size | 6 | ||
Maximum operating pressure | bar | 315 | |
Cracking pressure 1) | bar | 1.5 / 3 / 6 | |
Maximum flow | l/min | 60 | |
Direction of flow | see symbols | ||
Hydraulic fluid | see table | ||
Hydraulic fluid temperature range (NBR seals) | °C | -30 … +80 | |
Hydraulic fluid temperature range (FKM seals) | °C | -20 … +80 | |
Viscosity range | mm²/s | 2.8 … 500 | |
Maximum admissible degree of contamination of the hydraulic fluid 2) | Class 20/18/15 according to ISO 4406 (c) | ||
Area ratio | Without pre-opening | A1/A2 ~ 1/3.5 (see sectional drawing) | |
With pre-opening | A3/A2 ~ 1/12.5 (see sectional drawing) | ||
Version “SO60” | A1/A4 ~ 1/7 (see sectional drawing) |
1) | in free direction |
2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Selection of optimal sealing material also depends on the type of hydraulic fluid used.
Hydraulic fluid | Classification | Suitable sealing materials | Standards | |
Mineral oils | HL, HLP, HLPD | NBR, FKM | DIN 51524 | |
Bio-degradable | Insoluble in water | HETG | NBR, FKM | VDMA 24568 |
HEES | FKM | |||
Soluble in water | HEPG | FKM | VDMA 24568 | |
Flame-resistant | Water-free | HFDU, HFDR | FKM | ISO 12922 |
Containing water | HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) | NBR | ISO 12922 | |
Important information on hydraulic fluids!
Flame-resistant – containing water: Maximum operating pressure 210 bar Maximum hydraulic fluid temperature 60 °C Life cycle compared to operation with mineral oil HL, HLP 30 to 100 % |