4WRZEM

Rexroth
  • Size 10, 16, 25
  • Component series 1X
  • Maximum operating pressure 350 bar
  • Maximum flow 870 l/min

general

Type 4WRZEM
Size 10 16 25
Installation position any, preferably horizontal
Ambient temperature range °C -20 … +50
Storage temperature range °C -20 … +80
Weight kg 9 13.7 20.9
Weight with “D3” kg 9.5 14.2 21.4
Sine test according to DIN EN 60068-2-6 10 cycles, 10…2000.. 10 Hz with logarithmic frequency changing speed of 1 octave/min, 5 to 57 Hz, amplitude 1.5 mm (p-p), 57 to 2000 Hz, amplitude 10g, 3 axes
Noise test according to DIN EN 60068-2-64 20…2000 Hz, amplitude 0.05g2/Hz (10gRMS) 3 axes, testing time 30 min per axis
Shock test according to DIN EN 60068-2-27 Half-sine 15g / 11 ms, 3 times in positive and 3 times in negative direction per axis, 3 axes
Damp heat according to DIN EN 60068-2-30 Variant 2: +25 °C … +55 °C, 90 % … 97 % relative humidity, 2 cycles á 24 hours

hydraulic

Size 10 16 25
Maximum operating pressure bar 350
Maximum operating pressure Port P bar 315 350
Anschluss A bar 315 350
Port B bar 315 350
Operating pressure range External pilot oil supply bar 30 … 100
Pilot control valve without “D3”, internal pilot oil return bar 30 … 100
Internal pilot oil supply bar 100 … 315
Maximum return flow pressure Port T, external pilot oil return bar 315 250
Port T, internal pilot oil return bar 30
Port Y bar 30
Maximum flow l/min 170 460 870
Pilot flow input signal 0 → 100% Port X and Y l/min 3.5 5.5 7
Pilot volume switching process 0 → 100% cm³ 1.7 4.6 10
Hydraulic fluid see table
Hydraulic fluid temperature range °C -20 … +80
preferably °C -40 … +50
Viscosity range mm²/s 20 … 380
preferably mm²/s 30 … 46
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) Pilot control valve Class 18/16/13 according to ISO 4406 (c)
Main valve Class 20/18/15 according to ISO 4406 (c)
Hysteresis % ≤ 6
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

electrical

Size 10 16 25
Voltage type Direct voltage
Command value overlap % 20
Maximum solenoid current A 2.5
Maximum current consumption of the amplifier A 1.8
of the amplifier (impulse current) A 3
Solenoid coil resistance Cold value at 20 °C Ω 2
Maximum hot value Ω 3
Actuated time % 100
Maximum coil temperature 1) °C + 150
Protection class according to DIN EN 60529 IP65 (If a suitable and a correctly mounted mating connector are used.)
Power supply V 24
Supply voltage range V 19,4 … 35
Command value input “A1” V ± 10
Command value input range “F1” mA 4 … 20
1) Due to the surface temperatures occurring at the solenoid coils, the European standards ISO 13732-1 and EN 982 need to be adhered to.