STW 0195, STW 0196

Rexroth
  • Size 6, 10
  • Component series 2X, 1X

eneral

TypeSTW 0195STW 0196
Size610
Installation positionany, preferably horizontal
Ambient temperature range°C-20 … +50
Storage temperature range°C-20 … +80
Weightkg2.46.5

hydraulic

Size610
Maximum operating pressurePort P (sensor 50 bar)bar50
Port P (sensor 160 bar)bar160
Port P (sensor 250 bar)bar250
Port T (sensor 50 bar)bar50
Port T (sensor 160 bar)bar160
Port T (sensor 250 bar)bar210
Port A (sensor 50 bar)bar50
Port A (sensor 160 bar)bar160
Port A (sensor 250 bar)bar250
Port B (sensor 50 bar)bar50
Port B (sensor 160 bar)bar160
Port B (sensor 250 bar)bar250
Nominal flowP → Al/min65
A → T, B → Tl/min60
Control spool 1P → Al/min10
A → Tl/min20
Control spool 2P → Al/min20
A → Tl/min20
Maximum flowSee performance limits
Hydraulic fluidsee table
Hydraulic fluid temperature range°C-20 … +80
preferably°C+40 … +50
Viscosity rangemm²/s20 … 380
preferablymm²/s30 … 46
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)Class 20/18/15 according to ISO 4406 (c)
Hysteresis%≤ 0.1
Range of inversion%≤ 0.05
Response sensitivity%≤ 0.05
Zero shift upon change ofHydraulic fluid temperature%/10 K≤ 0.15
Operating pressure%/100 bar≤ 0.1
1)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
Hydraulic fluidClassificationSuitable sealing materialsStandards
Mineral oilHL, HLP, HLPD, HHVLP, HVLPDNBR / FKMDIN 51524
Bio-degradableInsoluble in waterHETGNBR / FKMISO 15380
HEESFKM
Soluble in waterHEPGFKMISO15380
Containing waterWater-freeHFDU, HFDRFKMISO 12922
Containing waterHFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620)NBRISO 12922
Important information on hydraulic fluids:
For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.

Flame-resistant – containing water:
Maximum pressure differential per control edge 50 bar
Pressure pre-loading at the tank port > 20% of the pressure differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP 50 % to 100 %

Bio-degradable and flame-resistant – containing water: If this hydraulic fluid is used, small amounts of dissolved zinc may get into the hydraulic system.

electrical

Size610
Voltage typeDirect voltage
Maximum current consumptionof the amplifierA2
of the amplifier (impulse current)A3
Maximum currentOutput stageA1.7
Signal partA0.3
Actuated time 1)%100
Maximum coil temperature 2)°C150
Protection class according to DIN EN 60529IP65 (If a suitable and a correctly mounted mating connector are used.)
Power supplyV24
Supply voltage rangeV19,4 … 35
Admissible residual rippleVpp2
Earthing (GND)V0
Enable input range“A6”V9 … 35
“F6”V9 … 35
Command value inputUQ “A6”mA10
Command value input rangeUP “A6”mA0 … 10
IQ and IP “F6”mA4 … 20
Actual value outputUQ “A6”V± 10
Actual value output rangeUP “A6”mA0 … 10
IQ and IP “F6”mA4 … 20
Control voltageLevel as for pin 1
0 V reference potentialFor pins 3, 6, 8 and 11 (connected to pin 2 in valve)
Error output24 V (19.4 V to 35 V), 200 mA maximum load
1)Connect the valve to the supply voltage only when this is required for the functional sequence of the machine.
2)Due to the surface temperatures occurring at solenoid coils, the European standards ISO 13732-1 and ISO 4413 need to be adhered to.

Sensor technology

Overload protectionSensor 50 barbar110
Sensor 160 barbar320
Sensor 250 barbar500
Bursting pressureSensor 50 barbar200
Sensor 160 barbar640
Sensor 250 barbar1000
Characteristic curve deviation%< 0.2
Hysteresis%< 0.1
Repetition accuracy%< 0.05
Setting time (10 … 90 %)ms< 1
Long-term drift (1 year) under reference conditions%< 0.1
ConformityCE according to EMC directive EN 61000-6-2 / EN 61326-2-3 and EN 61000-6-3 / EN 61326-2-3